Electrical system
1. 180 x 4.5 Clamp
2. 180 x 4.5 Clamp
KEY:
1. 180 x 4.5 Clamp
2. License Plate Light Connector
Checks and inspections
Battery recharge circuit
The recharge system consists of a three-phase generator with a permanent magneto flywheel.
The generator is directly connected to the voltage regulator.
This, in its turn, is connected directly to the ground lead and the battery positive terminal passing through
the 30A protective fuse.
This system requires, therefore, no connection to the key switch.
The three-phase generator allows a significant recharge power and at lower revs a good rapport is
achieved between generated power and idle stability.
Stator check
Stator winding check
WARNING
THIS CHECK CAN BE PERFORMED WITH THE STATOR PROPERLY INSTALLED