- Using a gauge, measure the height of the cams.
Specification
Specification
Standard axial clearance:
Maximum axial clearance allowed:
- If values measured are not within the specified
limits or there are signs of excessive wear, replace
the defective components with new ones.
- Check that the groove, shown in the figure, that
is the retention plate seat, exhibits no wear.
STANDARD HEIGHT
inlet
outlet
LIMITS ALLOWED
inlet
outlet
Desc./Quantity
33.774 mm
33.273
Desc./Quantity
33.526 mm
33.026 mm
0 ÷ 0.22 mm
0.3 mm
Engine