Injection
Fit the appropriate tool to check fuel pressure and
position the manifold over a graded container, with
a minimum capacity of 100 cm³. Connect the in-
jector with the cable that is part of the components
supplied for the injection tester. Connect the cable
terminals to an auxiliary battery. Activate the fuel
pump with the active diagnosis. Check that, within
15 seconds, approx. 70 cm³ of fuel is delivered at
a regulation pressure of about 3 BAR.
Specific tooling
020480Y Fuel pressure check kit
Carry out the injector sealing test
Dry the injector outlet with a blast of compressed
air. Activate the fuel pump. Wait for one minute
and make sure there are no leaks coming from the
injector. Slight oozing is normal.
Limit value = 1 drop per minute