set rmon history
B3(su)->show rmon history ge.1.1
Port: ge.1.1
-------------------------------------
Index 1
Owner
Status
Data Source
Interval
Buckets Requested = 50
Buckets Granted
Sample
Drop Events
Octets
Packets
Broadcast Pkts
Multicast Pkts
CRC Align Errors
set rmon history
Use this command to configure an RMON history entry.
Syntax
set rmon history index [port-string] [buckets buckets] [interval interval] [owner
owner]
Parameters
index‐list
port‐string
buckets buckets
interval interval
owner owner
Defaults
If buckets is not specified, the maximum number of entries maintained will be 50.
If not specified, interval will be set to 30 seconds.
If owner is not specified, monitor will be applied.
Mode
Switch command, read‐write.
Example
This example shows how configure RMON history entry 1 on port 
seconds:
B3(rw)->set rmon history 1 ge.2.1 interval 20
14-6 RMON Configuration
= monitor
= valid
= ifIndex.1
= 30
= 10
2779
Interval Start: 1 days 0 hours 2 minutes 22 seconds
= 0
= 0
= 0
= 0
= 0
= 0
Specifies an index number for this entry.
(Optional) Assigns this entry to a specific port.
(Optional) Specifies the maximum number of entries to maintain.
(Optional) Specifies the sampling interval in seconds.
(Optional) Specifies an owner for this entry.
Undersize Pkts
= 0
Oversize Pkts
= 0
Fragments
= 0
Jabbers
= 0
Collisions
= 0
Utilization(%)
= 0