Ip Irdp Minadvertinterval; Ip Irdp Holdtime - Enterasys SecureStack B3 Configuration Manual

Stackable switches
Table of Contents

Advertisement

Mode
Interface configuration: B3
Example
This example shows how to set the maximum IRDP advertisement interval to 1000 seconds on the 
VLAN 1 interface:
B3(su)->router(Config)#interface vlan 1
B3(su)->router(Config-if(Vlan 1))#ip irdp maxadvertinterval 1000

ip irdp minadvertinterval

Use this command to set the minimum interval in seconds between IRDP advertisements. The no 
form of this command deletes the custom holdtime setting, and resets the minimum 
advertisement interval to the default value of three‐fourths of the maxadvertinterval value, which 
is equal to 450 seconds.
Syntax
ip irdp minadvertinterval interval
no irdp minadvertinterval
Parameters
interval
Defaults
None.
Mode
Interface configuration: B3(su)‐>router(Config‐if(Vlan 1))#
Example
This example shows how to set the minimum IRDP advertisement interval to 500 seconds on the 
VLAN 1 interface:
B3(su)->router(Config)#interface vlan 1
B3(su)->router(Config-if(Vlan 1))#ip irdp minadvertinterval 500

ip irdp holdtime

Use this command to set the length of time in seconds IRDP advertisements are held valid. The no 
form of this command resets the hold time to the default value of three times the 
maxadvertinterval value, which is equal to 1800 seconds.
Syntax
ip irdp holdtime holdtime
no irdp holdtime
(su)‐>router(Config‐if(Vlan 1))#
Specifies a minimum advertisement interval in seconds. Valid values are 
3 to 1800.
ip irdp minadvertinterval
SecureStack B3 Configuration Guide 18-11

Advertisement

Table of Contents
loading

Table of Contents