Enterasys BL-89420ENT User Manual

Enterasys networks user's guide mid-span power hub 20-port and 10-port bl-89420ent, bl-89520ent, bl-89620ent, bl-89720ent, bl-89710ent
Table of Contents

Advertisement

Quick Links

Mid-Span Power Hub
20-Port and 10-Port
User's Guide
Title
P/N 9033928-02

Advertisement

Table of Contents
loading

Summary of Contents for Enterasys BL-89420ENT

  • Page 1 Mid-Span Power Hub 20-Port and 10-Port User’s Guide Title P/N 9033928-02...
  • Page 3: Regulatory Compliance Information

    Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made.
  • Page 4: Industry Canada Notice

    Industry Canada Notice This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté...
  • Page 5: Declaration Of Conformity

    In no event shall Enterasys Networks be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder. Enterasys Networks will in no case cover damages arising out of the product being used in a negligent fashion or manner.
  • Page 6 BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc. on behalf of itself and its Affiliates (as hereinafter defined) (“Enterasys”) that sets forth Your rights and obligations with respect to the Enterasys software program/firmware installed on the Enterasys product (including any accompanying documentation, hardware or media) (“Program”) in the package and prevails over any additional, conflicting or...
  • Page 7 APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the personal jurisdiction and venue of the Commonwealth of Massachusetts courts. None of the 1980 United Nations Convention on Contracts for the International Sale of Goods, the United Nations Convention on the Limitation Period in the International Sale of Goods, and the Uniform Computer Information Transactions Act shall apply to this Agreement.
  • Page 8 AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to Enterasys and its authorized representatives, upon reasonable notice, the right to audit and examine during Your normal business hours, Your books, records, accounts and hardware devices upon which the Program may be deployed to verify compliance with this Agreement, including the verification of the license fees due and paid Enterasys and the...
  • Page 9: Table Of Contents

    Chapter 3: Troubleshooting Appendix A: Hardware Specifications Regulatory Compliance Standards ... A-1 Product Standards ... A-1 20-Port Model BL-89420ENT, BL-89520ENT, BL-89620ENT, or BL-89720ENT ... A-1 10-Port Model BL-89710ENT ... A-2 20-Port Model Physical/Mechanical Specifications ... A-2 10-Port Model Physical/Mechanical Specifications ... A-2 LED Indicators/Module ...
  • Page 10 Figures BL-89420ENT, BL-89520ENT, BL-89620ENT, or BL-89720ENT 20-Port Mid-Span Power Hub 2-2 BL-89710ENT 10-Port Mid-Span Power Hub...2-2 BL-89420ENT, BL-89520ENT, BL-89620ENT, or BL-89720ENT Power Hub with Splitter...2-4 Individual Module for the 20- and 10-Port Chassis (BL-89400ENT, BL-89500ENT, BL-89600ENT, and BL-89700ENT) ...2-6 Tables Troubleshooting Checklist ...3-1...
  • Page 11: About This Guide

    Purpose This guide provides information and procedures on hardware installation, setup, configuration, and management of the Enterasys Networks 20-port and 10-port Mid-Span Power Hubs. Who Should Use This Guide Electrical Hazard: Only qualified personnel should perform the installation procedures described in this guide.
  • Page 12: Getting Help

    A description of any action(s) already taken to resolve the problem (e.g., changing mode switches, rebooting the unit, etc.) • The serial and revision numbers of all involved Enterasys Networks products in the network • A description of your network environment (layout, cable type, etc.) •...
  • Page 13: Chapter 1: Introduction

    Functions and Features The BL-89220ENT, BL-89420ENT, BL-89520ENT, BL-89620ENT, and BL-89720ENT 20-port Mid-Span Power Hub and the BL-89210ENT and BL-89710ENT 10-port Mid-Span Power Hub support applications in which AC power is difficult to access, such as VoIP phones, wireless LAN access points or Internet security cameras.
  • Page 14 Port Indicators 1-2 Introduction...
  • Page 15: Chapter 2: Installation And Connection

    Electrical Hazard: Only qualified personnel should install or service this unit. Verifying the Kit Unpack the unit and verify that you have all of the following items (See Figure 2-2 on page 2-2): • Enterasys’ 20-port or 10-port Mid-Span Power Hub •...
  • Page 16: Kit Contents

    10-port Mid-Span Power Hub may rack using the BL-89210-RMENT rack mount kit (optional). 2-2 Installation and Connection BL-89420ENT, BL-89520ENT, BL-89620ENT, or BL-89720ENT 20-Port Mid-Span Power Hub BL-89710ENT 10-Port Mid-Span Power Hub be placed on a shelf or mounted in a standard 19-inch...
  • Page 17: Technical Considerations

    Technical Considerations Before you mount the unit to a fixed location, consider the following: • Determine optimal placement. • Collect and document network information as required. • Ensure the cable length from the Ethernet network source to the powered device does not exceed 100 meters.
  • Page 18: Using A Splitter With The 20-Port And 10-Port Mid-Span Power Hubs

    5, 5e, or 6 shielded twisted pair straight-through cables. Figure 2-3 shows a typical configuration for the Enterasys 20-port Mid-Span Power Hub operating with a splitter. Figure 2-3 2-4 Installation and Connection BL-89420ENT, BL-89520ENT, BL-89620ENT, or BL-89720ENT Power Hub with Splitter...
  • Page 19: Powering Up

    If problems exist, refer to the troubleshooting checklist in If you require assistance, contact Enterasys Networks using one of the methods described “Getting Help” on page x.
  • Page 20: Individual Module For The 20- And 10-Port Chassis (Bl-89400Ent, Bl-89500Ent, Bl-89600Ent, And Bl-89700Ent)

    Powering Up Figure 2-4 Individual Module for the 20- and 10-Port Chassis (BL-89400ENT, BL-89500ENT, BL-89600ENT, and BL-89700ENT) 2-6 Installation and Connection...
  • Page 21: Chapter 3: Troubleshooting

    Refer to Table 3-1 for a checklist of problems and recommended actions to resolve the problem. If additional support is needed, refer to Table 3-1 Troubleshooting Checklist Problem Unit is plugged into the Enterasys Mid-Span Power Hub, but main power indicator is “off.”...
  • Page 22 Table 3-1 Troubleshooting Checklist (continued) Problem The Mid-Span Power Hub operates but one of the powered devices does not work. The Mid-Span Power Hub operates and the load device works, but there is no data link. The Mid-Span Power Hub operates but one of the ports is powering a load without turning the “Power"...
  • Page 23: Appendix A: Hardware Specifications

    Electromagnetic Compatability (EMC) Product Standards The equipment meets the following product standards: Standards 20-Port Model BL-89420ENT, BL-89520ENT, BL-89620ENT, or BL-89720ENT • 20 Female RJ45 Data input ports • Shielded jacks for Category 5 or greater UTP (two pair wire) or 100-ohm STP (two pair wire) •...
  • Page 24: 10-Port Model Bl-89710Ent

    10-Port Model BL-89710ENT • 10 Female RJ45 Data input ports • Shielded jacks for Category 5 or greater UTP (two pair wire) or 100-ohm STP (two pair wire) • Distance: Up to 100 meters, standard Ethernet distance • 10 Female RJ45 Data+Power on Ethernet (PoE-Power over Ethernet) output ports 20-Port Model Physical/Mechanical Specifications Table A-1 provides physical and mechanical specifications for the 20-port Mid-Span...
  • Page 25: Led Indicators/Module

    LED Indicators/Module Table A-3 LED States and Their Definitions LED Color Green Yellow Green Green Physical/Environmental Specifications Table A-4 Physical and Environmental Specifications Item Operating Temperature Storage Temperature Relative Humidity Operating Altitude State Detect Fuse Blown Power from Chassis Power Forwarding (48 V Out) Specification 0°...
  • Page 26: Electrical Specifications

    Electrical Specifications AC Power Input Voltage Connector Chassis Grounding Power Supply DC Port Power Output Power Enabling Power Pins Maximum Power/Port Maximum Power-all Ports Active Port to Port Isolation Overload Protection A-4 Hardware Specifications 90–264 V Autoranging (46 Hz–63 Hz) 3-pin with Ground Single IEEE 802.3af...
  • Page 27: Appendix B: Data/Power Splitter Specifications

    Data/Power Splitter Specifications This appendix lists Data/Power Splitter hardware and electrical specifications. Data/Power Splitter Hardware and Electrical Specifications Regulatory Compliance Standards This equipment meets the following safety and electromagnetic compatibility (EMC) requirements Safety Electromagnetic Compatability (EMC) Product Standards The equipment meets the following product standards: Standards Physical/Mechanical Specifications Table B-1 Physical/Mechanical Specifications...
  • Page 28: Electrical Specifications

    Electrical Specifications Table B-2 Electrical Specifications Item BL-89705ENT BL-89712ENT Physical/Environmental Specifications Table B-3 Physical and Environmental Specifications Item Operating Temperature Storage Temperature Relative Humidity B-2 Data/Power Splitter Specifications Specification 5 V @ 2.0 A 12 V @ 1.0 A Specification -20°...

Table of Contents