show rmon alarm
Syntax
show rmon alarm [index]
Parameters
index
Defaults
If index is not specified, information about all RMON alarm entries will be displayed.
Mode
Switch command, read‐only.
Example
This example shows how to display RMON alarm entry 3:
B3(rw)->show rmon alarm 3
Index 3
---------------------
Owner
Status
Variable
Sample Type
Interval
Rising Threshold
Rising Event Index
Table
14‐2 provides an explanation of the command output.
Table 14-2 show rmon alarm Output Details
Output
Index
Owner
Status
Variable
Sample Type
Startup Alarm
Interval
Rising Threshold
Falling Threshold
Rising Event Index
Falling Event Index
14-8 RMON Configuration
(Optional) Displays RMON alarm entries for a specific entry index ID.
= Manager
= valid
= 1.3.6.1.4.1.5624.1.2.29.1.2.1.0
= delta
= 30
= 1
= 2
What It Displays...
Index number for this alarm entry.
Text string identifying who configured this entry.
Whether this event entry is enabled (valid) or disabled.
MIB object to be monitored.
Whether the monitoring method is an absolute or a delta sampling.
Whether alarm generated when this entry is first enabled is rising, falling, or either.
Interval in seconds at which RMON will conduct sample monitoring.
Minimum threshold for causing a rising alarm.
Maximum threshold for causing a falling alarm.
Index number of the RMON event to be triggered when the rising threshold is
crossed.
Index number of the RMON event to be triggered when the falling threshold is
crossed.
Startup Alarm
Value
Falling Threshold
Falling Event Index = 0
= rising
= 0
= 0