5.25 TACACS Commands

5.25.1 tacacs-server host

The tacacs-server host command in global configuration mode specifies a TACACS+ host. To delete the specified name or
address, use the no form of this command.
Syntax
tacacs-server host {ip-address | hostname} [single-connection] [port port-number] [timeout timeout] [key keystring]
[source source] [priority priority]
no tacacs-server host ip-address
ip-address — Name or IP address of the host. An out-of-band IP address can be specified as described in the usage
guidelines.
hostname — Hostname of the tacacs server. (Range: 1 - 160 characters)
single-connection — Specify single-connection. Rather than have the device open and close a TCP connection to the
daemon each time it must communicate, the single-connection option maintains a single open connection between the
device and the daemon.
port-number — Specify a server port number. If unspecified, the port number defaults to 49. (Range: 0 - 65535)
timeout—Specifies the timeout value in seconds. If no timeout value is specified, the global value is used. (Range: 1 -
1000)
key-string — Specifies the authentication and encryption key for all TACACS communications between the device and
the TACACS server. This key must match the encryption used on the TACACS daemon. If no key string value is
specified, the global value is used. (Range: Up to 160 characters)
source — Specifies the source IP address to use for the communication. If no source value is specified, the global value
is used.
priority — Determines the order in which the servers will be used, when 0 is the highest priority. If unspecified defaults to
0. (Range: 0 - 65535)
Default Configuration
No TACAS host is specified
Command Mode
Global Configuration mode
User Guidelines
Multiple tacacs-server host commands can be used to specify multiple hosts.
If no host-specific timeout, key or source values are specified, the global values apply to each host.
To define TACACS server on the out-of-band port, use the out-of-band IP address format: oob/ip-address.
User's Manual of WGSD-1022/WGSD-8000
- 333 –