Table 35: EX Series Switch Environmental Tolerances

Environment Tolerance
Switch or
device
Altitude
EX2200-C
No performance
degradation up to
5,000 feet
(1524 meters)
EX2200
No performance
(except
degradation up to
EX2200-C
10,000 feet
switches)
(3048 meters)
EX2300-C
No performance
degradation up to
5,000 feet
(1524 meters)
EX2300
No performance
(except
degradation up to
EX2300-C
13,000 feet
switches)
(3962.4 meters) at
104° F (40° C) as per
GR-63
EX3200
No performance
degradation up to
10,000 feet
(3048 meters)
EX3300
No performance
degradation up to
10,000 feet
(3048 meters)
EX3400
No performance
degradation up to
10,000 feet
(3048 meters)
EX4200
No performance
degradation up to
10,000 feet
(3048 meters)
Copyright © 2017, Juniper Networks, Inc.
Table 35 on page 69
provides the required environmental conditions for normal switch
operation.
Relative Humidity
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
Chapter 6: Preparation Overview
Temperature
Normal operation ensured in the
temperature range 32° F (0° C)
through 104° F (40° C) at
altitudes up to 5,000 ft
(1,524 m).
For information about extended
temperature SFP transceivers
supported on EX2200 switches,
see Pluggable Transceivers
Supported on EX2200 Switches.
Normal operation ensured in the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operation ensured in the
temperature range 32° F (0° C)
through 104° F (40° C)
Normal operation ensured in the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operation ensured in the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operation ensured in the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operation ensured in the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operation ensured in the
temperature range 32° F (0° C)
through 113° F (45° C)
Seismic
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
69