Juniper EX4500 Hardware Manual page 261

Hide thumbs Also See for EX4500:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Table 65: Chassis Component Alarm Conditions on EX4500
Switches (continued)
Chassis
Component
Alarm Condition
Temperature
The temperature
inside the chassis
has exceeded
203° F (95° C).
The temperature
inside the chassis
has exceeded
185° F (85° C) and
a fan has failed.
The temperature
inside the chassis
has exceeded 80° C
(176° F).
The temperature
inside the chassis
has exceeded 70° C
(158° F) and a fan
has failed.
The temperature
sensor has failed.
Chapter 27: Alarms and Syslog Messages
Alarm
Severity
Remedy
Major
Replace the fan tray.
(red)
Open a support case using the Case
Manager link at
http://www.juniper.net/support/
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
Replace the fan tray.
(red)
Open a support case using the Case
Manager link at
http://www.juniper.net/support/
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Minor
Check the fan.
(yellow)
Open a support case using the Case
Manager link at
http://www.juniper.net/support/
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Minor
Replace the fan tray.
(yellow)
Open a support case using the Case
Manager link at
http://www.juniper.net/support/
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
Open a support case using the Case
(red)
Manager link at
http://www.juniper.net/support/
1-888-314-5822 (toll-free within the United
States and Canada) or 1-408-745-9500
(from outside the United States).
or
or
or
or
or call
239