Table 60: Cabling Requirements for a Virtual Chassis (continued)
Distance Between Virtual
Chassis Members
Greater than 5 m
Related
Documentation
118
Virtual Chassis Cable
Lengths Supported
NOTE:
With separately ordered Virtual Chassis cables, you can use the cable
connector retainers provided with the original cable; you can also use
separately ordered Virtual Chassis cable connector retainers.
Understanding EX Series Virtual Chassis Components
Understanding EX4200, EX4500, and EX4550 Virtual Chassis Hardware Configurations
on page 113
Virtual Chassis Cabling Configuration Examples for EX4200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX4500 Switches
on page 76
Details
To interconnect EX4200 switches that are installed farther
apart than 5 m, you must configure the SFP, SPF+, or XFP
uplink module ports or the SFP network ports in the
EX4200-24F switch as VCPs and use them to interconnect
the switches.
To interconnect EX4500 switches that are installed farther
apart than 5 m, you must configure either the uplink
module ports or the SFP+ network ports as VCPs and use
them to interconnect the switches.
To interconnect EX4550 switches that are installed farther
apart than 5 m, you must configure either the expansion
module ports or the network ports as VCPs and use them
to interconnect the switches.