EX4500 Switch Hardware Guide
172
You will see the following output (or something similar, depending on the hardware
being shut down):
user@switch> request system halt
warning: This command will halt all the members.
If planning to halt only one member use the member option
Halt the system ? [yes,no] (no) yes
*** FINAL System shutdown message from user@switch ***
System going down IMMEDIATELY
Shutdown NOW!
[pid 14102]
message sent
{master:0}
user@switch> Waiting (max 300 seconds) for system process `vnlru' to stop...done
Waiting (max 300 seconds) for system process `vnlru_mem' to stop...done
Waiting (max 300 seconds) for system process `bufdaemon' to stop...done
Waiting (max 300 seconds) for system process `syncer' to stop...
Syncing disks, vnodes remaining...3 3 1 2 2 0 0 0 0 done
syncing disks... All buffers synced.
Uptime: 38d18h0m6s
recorded reboot as normal shutdown
The operating system has halted.
Please press any key to reboot
CAUTION:
The final output of any version of this command is the "The
operating system has halted. Please press any key to reboot" message.
Wait at least 60 seconds after first seeing this message before following
the instructions in Steps 3 and 4 to power off the switch.
CAUTION:
If you have only one power supply in your switch, ensure that
you have halted your system safely before turning off the power supply.
Attach the ESD grounding strap to your bare wrist and connect the strap to the ESD
3.
point on the chassis.
Disconnect power from the switch by performing one of the following tasks:
4.
For AC power supplies:
If the AC power source outlet has a power switch. set it to the OFF (0) position.
If the AC power source outlet does not have a power switch, gently pull out the
male end of the power cord connected to the power source outlet.