Juniper EX4500 Hardware Manual page 214

Hide thumbs Also See for EX4500:
Table of Contents

Advertisement

EX4500 Switch Hardware Guide
192
Before you begin installing an uplink module in the switch, ensure that you have taken
the necessary precautions to prevent ESD damage (see
Discharge Damage" on page
Ensure that you have the following parts and tools available:
Electrostatic discharge (ESD) grounding strap (If a grounding strap is not available,
follow the alternative grounding method described in Step 1 of the following procedure.)
Phillips (+) screwdriver, number 2
To install an uplink module in an EX4500 switch (see
Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and
1.
connect the strap to the ESD point on the chassis.
If a grounding strap is not available, hold the uplink module in its antistatic bag in one
hand and touch the exposed, bare metal of the switch with the other hand to ground
yourself and the component.
If the uplink module slot has a cover panel on it, pull one of the ejector levers on the
2.
cover panel inward, to unseat the cover panel. Use this ejector lever to slide the cover
panel out. Save the cover panel for later use.
Taking care not to touch module components, pins, leads, or solder connections,
3.
remove the uplink module from its bag.
Loosen the captive screws in the ejector levers using the Phillips screwdriver, number
4.
2. Pull the ejector levers outward until they are fully open.
NOTE:
If you are removing an uplink module and installing another uplink
module, wait for at least 10 seconds after removing the uplink module
before installing the new or the same uplink module. If you do not wait for
at least 10 seconds, the interfaces on the uplink module might not come
up.
CAUTION:
Before you slide the uplink module into the slot on the switch
chassis, ensure the uplink module is aligned correctly. Misalignment might
cause the pins to bend, making the uplink module unusable.
Using both hands, place the uplink module in the empty slot and slide it in gently until
5.
it is fully seated.
281).
Figure 61 on page
"Prevention of Electrostatic
193):
Copyright © 2017, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Table of Contents