Connecting Power to an AC-Powered MX5, MX10, MX40, and MX80 Router

Copyright © 2017, Juniper Networks, Inc.
Chapter 15: Connecting the MX5, MX10, MX40, and MX80 Routers to Power

Figure 35: Grounding Points on MX5, MX10, MX40, and MX80 Routers

Tools and Parts Required for MX5, MX10, MX40, and MX80 Router Grounding and
Power Connections on page 87
Connecting Power to an AC-Powered MX5, MX10, MX40, and MX80 Router on page 89
Connecting Power to a DC-Powered MX5, MX10, MX40, and MX80 Router on page 91
CAUTION:
Do not mix AC and DC power supplies within the same router.
Damage to the router might occur.
You connect AC power to the router by attaching power cords from the AC power sources
to the AC appliance inlets located on the power supplies.
To connect the AC power cords to the router for each power supply:
Locate power cords that have a plug appropriate for your geographic location. For
1.
more information, see
"Connecting an MX5, MX10, MX40, and MX80 AC Power Supply
Cord" on page
139.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
2.
ESD points on the chassis.
Move the AC input switch next to the appliance inlet on the power supply to the off (
3.
position.
Connect the power cord to the power supply.
4.
Insert the power cord plug into an external AC power source receptacle.
5.
Protective
earthing terminal
(grounding points)
)
O