Program
Number
24-01-02
24-01-03
24-01-04
24-01-05
24-01-06
24-01-07
1 - 134
Program Name
System Options for Hold – Hold
Recall Callback Time
Exclusive Hold Recall Time
Exclusive Hold Recall Callback
Time
Forced Release of Held Call
System Options for Hold – Park
Hold Time - Normal
System Options for Hold – Park
Hold Time - Extended (Recall)
Description/Comments
A call that is parked longer than
the programmed interval recalls
the extension where it was initially
parked.
A call left on Exclusive Hold recalls
the extension that placed it on
Hold after this time.
An Exclusive Hold Recall rings an
extension for this time. If not
picked up, the call goes back on
System Hold.
Depending on the setting of
Program 14-01-16, the system
disconnects calls on Hold longer
than this time.
Set the Park Hold Time (0~64800
seconds). A call that is parked
longer than the programmed time
recalls the extension where it was
initially parked.
Refer to
Flexible System
Numbering on page 1-501
for
setting Flexible Timeouts for Class
of Service.
Set the Extended Park Hold Time
(0~64800 seconds). A call that is
parked longer than the
programmed time recalls the
extension where it was initially
parked.
Call Appearance (CAP) Keys
UNIVERGE SV8100
Assigned Data
0~64800 (seconds)
(default = 30)
0~64800 (seconds)
(default = 90)
0~64800 (seconds)
(default = 30)
0~64800 (seconds)
(default = 1800)
0~64800 (seconds)
(default = 90 seconds)
0~64800 (seconds)
(default = 300
seconds)

Hide quick links: