NEC UNIVERGE SV8100 Features & Specifications Manual page 538

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 5.0
Program
Number
21-01-03
21-01-09
22-01-03
22-01-04
22-01-06
24-01-01
24-01-02
24-01-03
24-01-04
1 - 528
Program Name
System Options for Outgoing
Calls – Trunk Interdigit Time
(External)
System Options for Outgoing
Calls – Ringdown Extension
Timer (Hotline Start)
System Options for Incoming
Calls – Ring No Answer Alarm
Time
System Options for Incoming
Calls – DIL No Answer Recall
Time
System Options for Incoming
Calls – DID Ring-No-Answer
Time
System Options for Hold – Hold
Recall Time
System Options for Hold – Hold
Recall Callback Time
System Options for Hold –
Exclusive Hold Recall Time
System Options for Hold –
Exclusive Hold Recall Callback
Time
Description/Comments
Program how long an extension
must wait before using the
Barge-In feature can be used on a
call (this timer waits until it expires
before putting a call in a talk state).
This timer also affects Voice Over.
After the user lifts the handset, the
extension automatically calls the
ringdown destination after this
interval. A setting of 0 immediately
rings the programmed extension.
Any other setting delays the
ringdown the number of seconds
programmed.
Set the Ring No Answer Alarm
interval. If a trunk rings a multiline
terminal longer than this interval,
the system changes the ring
cadence.
A DIL that rings its programmed
destination longer than this
interval diverts to the DIL No
Answer Ring Group (set in
Program 22-08).
Set the DID Ring No Answer
(RNA) Intercept time (0~64800
seconds). In systems with RNA
Intercept, the DID call rings the
destination extension for this time,
and then rings Intercept Ring
Group.
Set the Hold Recall Time. A call
on Hold recalls the extension that
placed it on Hold after this time.
Set the Hold Recall Callback Time.
A trunk recalling from Hold rings
an extension for this time.
Set the Exclusive Hold Recall
Time. A call on Exclusive Hold
recalls the extension that placed it
on Hold after this time.
Set the Hold Recall Time. A trunk
recalling from Hold rings an
extension for this time. If still
unanswered, the call changes to
System Hold.
UNIVERGE SV8100
Assigned Data
0~64800 seconds
(default = 5 seconds)
0~64800 seconds
(default = 5 seconds)
0~64800 (seconds)
(default = 60 seconds)
0~64800 (seconds)
(default = 0 seconds)
0~64800 (seconds)
(default = 20 seconds)
0~64800 (seconds)
(default = 90 seconds)
0~64800 (seconds)
(default = 30 seconds)
0~64800 (seconds)
(default = 90 seconds)
0~64800 (seconds)
(default = 30 seconds)
Flexible Timeouts