NEC UNIVERGE SV8100 Features & Specifications Manual page 739

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program
Number
14-07-01
15-06-01
15-07-01
20-06-01
Night Service
Program Name
Trunk Access Map Setup
Trunk Access Map for
Extensions
Programmable Function Keys
Class of Service for Extensions
Description/Comments
To allow for Universal Night
Answer (UNA) answering, set up
the Trunk Access Maps (1~200).
For UNA, extension must have
incoming access to trunk ringing
the External Paging speakers.
For Universal Night Answer (UNA)
answering, assign Trunk Access
Maps (1~200) to extensions. Make
one entry for each Night Service
mode.
Assign Night Service function keys
(09) to extensions and set the key
for the proper mode (Day, Night,
Rest, etc.). If the additional data is
set to 0, the toggle mode is
assigned.
Assign a Class of Service (1~15)
to an extension.
Issue 5.0
Assigned Data
0 = No access
1 = Outgoing access
only
2 = Incoming access
only
3 = Access only when
trunk on Hold
4 = Outgoing access
and access when trunk
on Hold
5 = Incoming access
and access when trunk
on Hold
6 = Incoming and
Outgoing access
7 = Incoming access,
outgoing access and
access when trunk
on Hold
Trunk Access Maps:
1~200
Default:
Access Maps 1~200 =
Trunk Ports 1~200
assigned with option 7
access (incoming and
outgoing access and
access when trunk is
on Hold).
Trunk Access Maps:
1~200
(default = 1)
For Line Keys: 1~48
0 ~ 99 (Normal
Function Code)
(default = Service
*
*
Code 851)
00 ~
99
(Appearance Function
Code) (default =
Service Code 852)
Day Night/Mode: 1~8
Class of Service of
Extensions (1~15)
Default:
All extension port =
Class 1
1 - 729

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents