Siemens SINUMERIK 828D Programming Manual page 31

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

<limit values>
<access rights>
<init_time>
<init_value>
Job planning
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
:
Lower and/or upper limit value
<limit value>:
LLI
<limit value>:
ULI
See "Attribute: Limit values (LLI, ULI) (Page 36)"
Note
Cannot be redefined for:
• System variables
• Global user data (GUD)
• Data types:
:
Access rights for reading/writing via part program or OPI
<protection
APX
level>:
<protection
APRP
level>:
<protection
APWP
level>:
<protection
APRB
level>:
<protection
APWB
level>:
See "Attribute: Access rights (APR, APW, APRP, APWP, APRB,
APWB) (Page 40)"
:
Point in time at which the variable is reinitialized
:
INIPO
:
INIRE
:
INICF
:
PRLOC
See "Attribute: Initialization value (Page 33)"
:
Initialization value
When redefining the initialization value, an initialization time always
has to be specified also (see <init_time>).
See "Attribute: Initialization value (Page 33)"
For the initialization of array variables:
See "Definition and initialization of array variables (DEF, SET, REP)
(Page 46)"
Note
Cannot be redefined for:
• System variables, with the exception of setting data
Lower limit value (lower limit)
Upper limit value (upper limit)
,
,
,
BOOL
AXIS
STRING
FRAME
Execute: NC language element
Read: Part program
Write: Part program
Read: OPI
Write: OPI
Protection
level
POWER ON
End of main program, NC reset or POWER ON
NewConfig or end of main program, NC reset or
POWER ON
End of main program, NC reset following local
change or POWER ON
Flexible NC programming
1.1 Variables
Range of values: 0 to 7
31