Siemens SINUMERIK 828D Programming Manual page 21

Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Significance
$A_DLB
$A_DLW
$A_DLD
$A_DLR
<index>
Job planning
Programming Manual, 07/2010, 6FC5398-2BP40-0BA0
:
Link variable for BYTE data format (1 byte)
Data type:
Range of values:
:
Link variable for WORD data format (2 bytes)
Data type:
Range of values:
:
Link variable for DWORD data format (4 bytes)
Data type:
Range of values:
:
Link variable for REAL data format (8 bytes)
Data type:
Range of values:
:
Address index in bytes, counted from the start of the link variable memory
Data type:
Range of values:
UINT
0 to 255
INT
-32768 to 32767
INT
-2147483648 to 2147483647
REAL
±(2,2*10
... 1,8*10
-308
+308
INT
0 - MAX_INDEX
Note
• MAX_INDEX is calculated from the parameterized
size of the link variables memory: MAX_INDEX =
(MD18700 $MN_MM_SIZEOF_LINKVAR_DATA) - 1
• Only indices may be programmed, so that the bytes
addressed in the link variables memory are located on
a data format limit ⇒
Index = n * bytes, where n = 0, 1, 2, etc.
: i = 0, 1, 2, etc.
$A_DLB[i]
: i = 0, 2, 4, etc.
$A_DLW[i]
: i = 0, 4, 8, etc.
$A_DLD[i]
: i = 0, 8, 16, etc.
$A_DLR[i]
Flexible NC programming
1.1 Variables
)
21