NOTICE
Severe engine damage can occur in as little as
15 seconds if the engine is started without
supplying water to the cooling system.
Never start the motor without supplying water
to the cooling system.
1. Install the flushing attachment 1 so that the
water intake holes are covered by the rubber
cups on the attachment.
2. Connect a garden hose to the flushing
attachment and turn on the water to obtain
enough flow so that plenty of excess water is
flowing out from around the rubber cups on
the attachment.
3. Place the remote control handle in the
"NEUTRAL" position with the propeller
removed, start the motor and allow it to run
at idle.
4. Readjust the water flow, if necessary, so that
there is still plenty of excess water flowing
out from around the rubber cups.
5. Allow the water to continue circulating for a
few minutes.
6. Stop the motor, then turn off the water.
7. Remove the flushing attachment from the
water intake hole.
8. Clean the motor surface and apply a coat of
automotive wax on the external finish of the
motor.
46
ENGINE NOT RUNNING
– Vertical position –
1. Remove the plug A from the flushing port.
2. Install garden hose by using a hose connec-
tor matched to flushing port thread B.
Thread B: 0.75 – 11.5 NHR (American stan-
dard hose coupling threads for garden hose
applications.)
3. Turn on the water to obtain a good water
flow. Flush the engine for about five minutes.
4. Turn off the water.
5. Remove the hose and connector (if used)
then reinstall the plug into the flushing port.
6. Leave the motor in a vertical position until
the engine is drained completely.
ENGINE NOT RUNNING
– Full tilt up position –
1. Raise the engine to the full tilt up position.
2. Follow the "ENGINE NOT RUNNING – Verti-
cal position" instructions.
DO NOT RUN ENGINE IN THE FULL TILT
UP POSITION.
3. Lower the motor to a vertical position until
the engine is drained completely.