MACHINE INSTALLATION
1.2.11 METER CHARGE (MACHINE INSTALLATION)
If the customer has a service contract, change the settings of the following SP
modes depending on the contract type.
Item

Meter charge

Counting method
Fax No. setting
Counter reset
NOTE: 1) The default setting for this machine is meter-charge mode off.
2) The meter-charge counter cannot be reset.
G081/G092
SP No.
SP5-930-1
Specifies whether the meter charge
mode is enabled or disabled.
Meter charge mode enabled:
The Counter menu appears
immediately after the Menu key is
pressed.
The counter type selected by the
counting method (SP5-045-1) can
be displayed with the Counter
menu.
The counter values can also be
printed with the Counter menu.
The selected counter starts from a
negative number.
The PM warning is not displayed
when the replacement time
arrives.
Meter charge mode disabled:
The Counter menu is not
displayed.
The total counter starts from 0.
SP5-045-1
Specifies whether the counting
method used in meter charge mode is
based on developments or prints.
Important:
This SP can only be done before the
negative counters are reset with SP7-
825-001
SP5-812-2
Programs the service station fax
number.
The number is printed on the counter
list when the meter charge mode is
selected, so that the user can fax the
counter data to the service station.
SP7-825-1
Resets the counters to 0.
Important: This must be done at
installation after all the above settings
have been finished. The negative
counters used in meter charge mode
will be reset to zero.
Function
1-22
Default
Off
Developments
SM