3.9 IH (INDUCTIVE HEATER) UNIT

NOTE: After removing the fusing unit, use
caution not to push the thermostat
[A][B]. The thermostat can be
easily broken.
• Fusing unit (! 3.2)
• All covers (! 3.4)
[C]: Interlock switch cover
( x 3)
[D]: IH cable shield cover ( x 1)
[E]: Cover ( x 1)
[F]:  x 2 (pink+white, black)
[G]: IH harness cover ( x 1)
[H]: IH unit ( x 1, 1 washer)
NOTE: Pull out the IH harness
cable [I] through the
opening in cover [J].
[J]: IH shield cover ( x 1, 2 hooks [K])
SM
IH (INDUCTIVE HEATER) UNIT
[C]
[J]
3-27
[A]
[B]
G081R104.WMF
[F]
[D]
[E]
G081R935.WMF
[G]
[H]
G081R936.WMF
[K]
G081/G092
[I]

Advertisement