Temperature detection
The thermistor signals, TH1HIGH and TH2HIGH, indicate that the temperature of
the fusing belt has become too high. The TH1HIGH circuit is closed when
0
thermistor 1 [
] detects high temperature in the middle of the fusing belt. The
TH2HIGH circuit is closed when thermistor 2 [
far side (rear) of the fusing belt. The signal TH1HIGH is used to control the fusing
temperature ( ) Fusing temperature control ). The table lists the pin locations.
(Refer to illustration on pg. 6-29.)
Signal
Name
CN15
TH1HIGH
2
TH2HIGH
3
NOTE: If several sheets of narrow-width paper are continuously fed, the
temperature at the ends of the belt become much higher than the
temperature in the middle. Thermistor 2 (TH2HIGH) prevents the ends of
the belt from overheating.
SM
Pin No.
CN1601
CN15
6
In
5
In
6-31
0
] detects high temperature at the
In/Out
CN1601
Detects high temperature
Out
in the middle of the belt
Detects high temperature
Out
at the rear end of the belt
CN15: On engine control board
CN1601: On fusing unit