Dodge RAM TRUCK 1500 1995 Service Manual page 356

Table of Contents

Advertisement

BR
BATTERY/STARTING/CHARGING SYSTEMS DIAGNOSTICS
8A - 23
BATTERY SPECIFICATIONS
S P E C I F I C A T I O N S
BATTERY CLASSIFICATIONS
AND
RATINGS
Load Test
( A m p s )
Cold Cranking
Rating @ 0°F
Reserve
Capacity
3 0 0 A m p
600 Amp
120 Minutes
405 Amp
750 Amp
150 Minutes
CRANKING
R A T I N G
is the
c u r r e n t a
battery can
d e l i v e r for 3 0 s e c o n d s
and
m a i n t a i n a t e r m i n a l
voltage
of
7.2 volts or greater
at specified temperature.
R E S E R V E CAPACITY RATING is the length of time a battery can deliver 25 amps and maintain a minimum terminal voltage
of 10.5 volts at 27°C (80T).
J958A-14
STARTING SYSTEM SPECIFICATIONS
V-6 AND V-8 ENGINE
STARTER
SPECIFICATIONS
V-10 ENGINE
STARTER
SPECIFICATIONS
Manufacturer
Nippondenso
Engine Application
5.91, 5.2L & 3.9L
Part Number and
53005984
• Power Rating
1.4
Kw
Voltage
12
1
No. of Fields .
4
No. of Poles
4
Brushes
4
Drive
Reduction
Gear Train
Free Running Test
Voltage
11
Amperage Draw
73 Amps
Minimum Speed rpm
3601 rpm
Solenoid Closing Voltage
7.5 Volts
Cranking Amperage Draw Test . . .
125-250 Amps*
j
* Engine should be up to operating temperature. Extremely heavy
oil or tight engine will increase starter amperage draw.
J948B-26
M a n u f a c t u r e r
N i p p o n d e n s ©
Engine Application
8.0L
Part Number and
Power Rating
56004757
1.4 kw
Voltage
12
No. of Fields
4
No. of Poles
4
Brushes
4
Drive
Reduction
Gear Train
Reduction
Gear Train
Free Running Test
Voltage
11
73 Amps
3601 rpm
Amperage Draw
Minimum Speed rpm
11
73 Amps
3601 rpm
Solenoid Closing Voltage
7.5 Volts
Cranking Amperage Draw Test . . . .
125-250 Amps*
* Engine should be up to operating temperature. Extremely
heavy oil or tight engine will increase starter amperage draw.
J948B-25
DIESEL
ENGINE
STARTER
SPECIFICATIONS
R E D U C T I O N G E A R S T A R T E R
M a n u f a c t u r e r
N i p p o n d e n s o
Engine Application
5.9L DIESEL
Part Number and
Power Rating
4741012
2.7 kw
Voltage
12
No. of Fields
4
No. of Poles
4
Brushes
4
Drive
Conventional
G e a r Train
Conventional
G e a r Train
Free Running Test
Voltage
11
200 Amps M a x .
3000 rpm Min.
Amperage Draw
Minimum Speed rpm
11
200 Amps M a x .
3000 rpm Min.
Solenoid Closing Voltage
8 Volts
Cranking Amperage Draw Test . . . .
4 5 0 - 7 0 0 Amps*
* Engine should be up to operating temperature. Extremely
heavy oil or tight engine will increase starter amperage draw.
J948B-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ram truck 3500 1995Ram 1995