Event Log Table
From here, you can view specific event logs for the Switch. Choose an event log you wish to view from
the drop down list.

Alarm List

You can configure network alarms to occur when a network problem is detected. Choose your
preferences for the alarm from the drop down boxes.
Index
Sample Port
Sample Variable
Sample Interval
Sample Type
Rising Threshold
Falling Threshold
Rising Event
Falling Event
Owner
Click the Apply button
Enter the entry number for the Alarm List.
Select the port from which the alarm samples were taken.
Select the variable of samples for the specified alarm sample.
Enter the alarm interval time.
Select the sampling method for the selected variable and comparing the
value against the thresholds.
Absolute: Compares the values with the thresholds at the end of the
sampling interval.
Delta: Subtracts the last sampled value from the current value.
Enter the rising number that triggers the rising threshold alarm.
Enter the falling number that triggers the falling threshold alarm.
Enter the event number by the falling alarm are reported.
Enter the event number by the falling alarms are reported.
Enter the Switch that defined the alarm.
to accept the changes or the Cancel button
to discard them.