Siemens SCALANCE W788-1PRO Operating Instructions Manual page 259

Hide thumbs Also See for SCALANCE W788-1PRO:
Table of Contents

Advertisement

Traps
Name
snScalanceWPowerLi
neDown
snScalanceWPowerLi
neUp
snScalanceWFault
snScalanceWIQOS
snScalanceWLinkChe
ckOff
snScalanceWLinkInte
grityOn
snScalanceWClientAu
thenticated
snScalanceWClientDe
Authenticated
snScalanceWRedund
ancy
snScalanceWOverlap
AP
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
Specific
Variable
Index
31
snScalanceWChangedPowerLin This is g
e - The power line where the
last power down occurred. 1-
M12, 2-Ethernet Power
snScalanceWChangedPowerLin
32
e - The power line where the
last power up occurred. 1-M12,
2-Ethernet Power
41
snScalanceWFaultValue -
Fault value:
0 = no fault,
bit 0 = power M12 is off,
bit 1 = link down,
bit 2 = internal error,
bit 23 = Link Check error,
bit 24 = IP Alive broken,
bit 25 = power ethe
bit 26 = Cold/warm start,
bit 27 = C-PLUG error,
bit 28 = iQoS error,
bit 29 = Redundancy error"
51
snScalanceWIQOSValue -
Description of the last
snScalanceWIQOS trap
81
snScalanceWLinkCheckValue -
Description of the last
snScalanceWLinkCheckOff
Trap
82
snScalanceWLinkCheckValue -
Description of the last
snScalanceWLinkCheckOn trap
85
SnScalanceWClientsIndex - An
index of the client in the
snScalanceWClients table
86
SnScalanceWClientsIndex - An
index of the client in the
snScalanceWClients table
53
SnScalanceWRedundancyValu
e- Description of the last
redundancy trap.
SnScalanceWRedundanc
- Status of redundancy
connection
101
snScalanceWOverlapAPValue
- Description of the last
OverlapAP trap.
enerated if there is a
power down on M12 or the
Ethernet power connector.
This is generated if there is a
power up on M12 or the
Ethernet power connector.
This is generated if the
snScalanceWFaultValue
variable is changed.
The bit is set to "1" accord
the event that has occurred.
rnet is off,
This is generated if a timeout
occurs with
with Link Check.
This is generated if a client
monitor
ed with Link Check logs
on again at the AP following a
timeout.
This is generated when a cl
logs on at the AP.
This is generated when a clie
logs off from the AP.
This is generated if th
the redundant connection
changes, for example when the
connection of wireless interface
yState
A aborts.
Is generated when an access
point is detected on the device's
own or an overlapping wireless
channel.
Appendix
Description
ing to
a client monitored
ient
nt
e status of
259