Configuration Using Web Based Management and the Command Line Interface
Modify C-PLUG list box, Modify button
You can only make settings in this box if y
Here, you decide how you want to change the content of the C-PLUG. The
following alternatives are possible:
After making your selection, start the function by clicking the Modify button.
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
Copy inter
nal Configuration to C-PLUG
The configuration in the internal flash memory of the switch is copied to
the C-PLUG; this is followed by a restart.
There is one important use case for this function: The device has started
up with a C-PLUG containing a bad configuration or a configuration
different from the device. If you have not yet made any configuration
changes after starting up the device, you can use this function to
overwrite the content of the C-PLUG with the original device
configuration.
Load default Configuration to C-PLUG and Restart
A configuration with all the factory default values is stored on the C-
PLUG. This is followed by a restart in which the SCALANCE W78x starts
up with these default values.
Clean C-PLUG (Low Level Format, Configuration lost)
Deletes all data on the C-PLUG and starts a low-level formatting function.
There is no automatic restart.
Create PRESET PLUG
Writes configuration data to a PRESET PLUG. For detailed information
on this topic, refer to Section 3.4
ou are logged on as administrator.