Configuration Using Web Based Management and the Command Line Interface
Example: A WDS connecti
connection. With the setting ForceTrue, a direct connection is assumed. With
Auto, a direct connection is not assumed.
Enabled
Shows whether spanning tree is enabled or disabled for the port.
Configurat
ion of a Port for (Rap
If you click on a port name in the first column, you open the (Rapid) Spanning Tree
Port Properties page:
STP enabled check box
Enable this check box, if you want the port to use the (rapid) spanning tree
protocol.
Priority text box
Here, enter a value between 0
and 255 for the port priority.
Admin Path Cost text box
Here, you can enter a value for the STP or RSTP Path Cost parameter. The
relevant value is then used depending on the selected version.
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
on between access points is always a half duplex
id) Spanning Tree