Siemens SCALANCE W788-1PRO Operating Instructions Manual page 172

Hide thumbs Also See for SCALANCE W788-1PRO:
Table of Contents

Advertisement

Configuration Using Web Based Management and the Command Line Interface
Synta of the Command Line In
x
CLI\SECURITY\BASIC\WLAN1>VAP1
or for the sec
ond wireless adapter (if it exists)
CLI\SECURITY\BASIC\WLAN2>VAP1
Command
authent
[0|1|2|3|
4|5|6|7|8]
encrypt [E|D]
cipher [OFF
|AUTO|
WEP|
AES|TKI
P]
defkey [1|2|3|4]
wpaphrase [WPA password]
grkint [inter
val]
supssid [E|D]
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
terface
Description
Specifies the authentication type.
For the parameter n, enter a number
between 0 and 4 for the type
authentication:
0
Open System
1
Shared Key
2
WPA (RADIUS)
3
WPA-PSK
4
802.1x (RADIUS)
5
WPA2
6
WPA2-PSK
7
WPA-Auto
8
WPA-Auto-PSK
Encryption enabled / disabled.
Specifies the encryption scheme.
Selects the default WEP key.
Enter the WPA-PSK password.
Specifies th
e "Group Key
Intervals" in
WPA-PSK.
Enable / disable Close Wireless
System functionality.
Comment
With the authentication
types 7 (WPA-Auto)
(WPA-Auto-PSK), the
encryption method of
WPA and WPA2 or
WPA-PSK & WPA2-PSK
must be the same.
The password can be 8 to
63 ASCII characters or
exactly 64 hexadecimal
characters long.
Update
Interval in seconds,
(0; 36...
36000), 0 =
and 8
OFF
172

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w788-1rrScalance w788-2rrScalance w788-2pro

Table of Contents