Configuration Using Web Based Management and the Command Line Interface
Syntax of the Command Line Interface
CLI\SYSTEM\SNMP>
Command
snmp [E|D]
snmpv1 [E|D]
snmpv3 [E|
D]
snmpro [E|D]
getcomm
[Read community string]
setcomm
[Write community string]
traps [E|D]
Operating Instructions SCALANCE W78x
C79000-G8976-C184-07
Description
Enables / disables SNMP.
Enables / disables SNMPv1/v2c.
Enables / di
sables SNMPv
Enables / disables SNMPv1/v2c
read only.
Specifies the Read community
string, maximum length 6
characters.
Specifies the Write community
string, maximum length 63
characters.
Enables / disables SNMPv1 traps.
Comment
Enables / disables
SNM
Pv1, v2c, v3 and
Traps.
Enables / disables
SNMPv1, v2c and traps.
3.
The spe
cial features
SNMPv3 undertake effect
after you disable
SNMPv1. Enabling
SNMPv3 does not
automatically disable
SNMPv1.
The default is public.
3
The default is private.
Traps are then enabled, if
SNMP v1, v2c is
enabled.