Field
Lamp On
Aiming Pattern On
Brightness
Exposure (ms)
Analog Gain
C-8
Table C-1. AcqCap Fields (Continued)
Specifies if the lamp should be used during image
acquisition. If enabled, the lamp is turned on during
the exposure phase of image acquisition.
The default value is Disabled. Allowed values are
Enabled (TRUE) or Disabled (FALSE).
Specifies if the aiming reticule should be enabled.
If enabled, the aiming reticule is turned on as image
acquisition is started. The aiming reticule
automatically turns off during the exposure phase
of image acquisition so that it does not appear in
the captured image.
The default value is Disabled. Allowed values are
Enabled (TRUE) or Disabled (FALSE).
Specifies the target brightness that the auto
exposure algorithm attempts to achieve. This
feature is only meaningful when auto exposure is
enabled.
The default value is 200. Allowed values are 2 -
254.
Specifies the exposure time in microseconds. The
field is disabled, and its current value is ignored, if
the auto exposure is enabled.
The default value is 16320. Allowed values are
64 - 32704, step 64.
Specifies the amount of analog gain to apply. The
field is disabled, and its current value is ignored, if
the auto exposure is enabled.
The default value is 95. Allowed values are 0 - 127.