Symptom
Attempt by the terminal to
ActiveSync failed.
During communications,
no data was transmitted,
or transmitted data was
incomplete.
12-16
Table 12-5. Troubleshooting The CRD 8100-4200E
Cause
Terminal removed from
the cradle while the LED
was blinking green.
ActiveSync on the host
computer has not yet
closed the previous
ActiveSync session.
Incorrect cable
configuration.
Communications software
improperly configured.
Terminal ActiveSync
disabled or not configured
to accept network
connection.
Host ActiveSync disabled
or not configured to
accept network
connection.
Terminal removed from
cradle during
communications.
Terminal has no active
connection.
Solution
Wait one minute and reinsert the terminal in
the cradle. This allows the cradle to attempt
another synchronization.
Wait one minute and reinsert the terminal in
the cradle. This allows the cradle to attempt
another synchronization.
Check your DHCP server and determine
which IP address was allocated to the
cradle, then check connectivity by pinging
the cradle.
Perform setup as described in
Communication Setup
your DHCP server and determine which IP
address was allocated to the terminal slot,
then check connectivity by pinging the
cradle.
On the terminal, uncheck Start - ActiveSync
- Tools - Options - PC - Enable
synchronization when cradled using:.
On the host computer, check File -
Connection Settings - Allow network
(Ethernet) Server Connection with this
desktop computer.
Replace terminal in cradle and
retransmit.
An icon will be visible in the status bar if a
connection is currently active.
on page 4-6. Check

Advertisement