Table 12-7. Troubleshooting The VCD 8100-R001
Symptom
Spare battery is not
charging.
Terminal not
communicating
through the serial
cable.
Note: If, after performing these checks, the terminal is still not reading
symbols, contact your distributor or Symbol Technologies.
12-22
Cause
Battery not correctly seated
in charging slot.
Battery inserted incorrectly.
Battery is faulty.
The serial cable is not fully
connected.
The terminal is not fully
seated in the cradle.
Solution
Remove and re-insert the spare battery into
slot, making sure it is firmly seated (see page
4).Check slot for debris. Ensure battery status
indicator LED turns on.
Ensure the contacts facing down and toward
the opening of the spare battery slot.
Verify that other batteries charge properly. If so,
replace the faulty battery.
Ensure the serial cable is connected securely to
both the cradle and to the host computer.
Remove and re-insert the terminal into the
cradle, making sure it is firmly seated.