PDT 8100 Series with Intel XScale Technology Product Reference Guide
Table 12-5. Troubleshooting The CRD 8100-4200E (continued)
Symptom
Battery is not recharging.
Warning Message - "!
Unable to obtain a server
assigned IP address. Try
again later or enter an IP
address in Network
Settings."
12-18
Cause
Terminal removed from
the cradle too soon.
Battery is faulty.
Terminal is not inserted
correctly into the cradle.
This message occurs if a
suspend/resume cycle is
performed and the
terminal radio is not
associated (e.g. due to
being out of range)
Solution
Replace the terminal into the cradle. It can
take up to 4 hours to recharge a completely
depleted battery pack if terminal is
suspended or longer if the terminal is on.
Tap Start - Settings - System - Power to
view battery status.
Verify that other batteries charge properly. If
so, replace the faulty battery.
Remove the terminal and reinsert it
correctly. Verify charging is active. Tap Start
- Settings - System - Power to view battery
status.
Tap OK to close the message. The terminal
will obtain address information and
communicate through the ethernet cradle.