Redeployment Vm Management R1.0X; Redeployment Vm Management R1.1 And Upper - Alcatel-Lucent OpenTouch Troubleshooting Manual

Hide thumbs Also See for OpenTouch:
Table of Contents

Advertisement

Alcatel-Lucent OpenTouch R1.x Troubleshooting guide
virsh undefine vmOXE
virsh undefine vmManagement
virsh undefine vmConverter
re-define again the virtual machine :
virsh define /mnt/virtualmachines/images/vmOXE.xml
virsh define /mnt/virtualmachines/images/vmManagement.xml
virsh define /usr/kvm/vmConverter
then via the virt-manager : Run the virtual machine

4.2.4 Redeployment VM management R1.0x

Stop the vmManagement $BICS_HOME/bin/management_cmd forcestop
Delete the old vmManagement file : rm /var/lib/libvirt/images/vmManagement.img
Concatenate and unzip the 2 vmManagement files :
copy the vmManagement_dvd1.iso and vmManagement_dvd2.iso files in the /mnt
mkdir /mnt/dvd1
mkdir /mnt/dvd2
mount –o loop /mnt/vmManagement_dvd1.iso /mnt/dvd1
mount –o loop /mnt/vmManagement_dvd2.iso /mnt/dvd2
cat /mnt/dvd1/vmManagement.img.gz0 /mnt/dvd2/vmManagement.img.gz1 > vmManagement.img.gz
gunzip –c /mnt/vmManagement.img.gz > /var/lib/libvirt/images/vmManagement.img
start the vmManagement : $BICS_HOME/bin/management_cmd start
go to windows and launch the c:/temp/postfactory/postfactory.vbs script (Note : the windows password is
default password Sdfghjk1 see in the installation manual/VMmanagement postinstallation). Caution : you
have to wait that windows stops automatically, the postfactory.vbs could be very long until a hour.
do not forget to replace the nmc.license file in c:\etc\
on the server launch the "management_cmd updatekey" command

4.2.5 Redeployment VM management R1.1 and upper

Stop vmManagement $BICS_HOME/bin/management_cmd forcestop
Delete the old vmManagement file : rm /mnt/virtualmachines/images/vmManagement.img
Concatenate and unzip the 2 vmManagement files :
copy the vmManagement_dvd1.iso and vmManagement_dvd2.iso files in the /mnt
mkdir /mnt/dvd1
mkdir /mnt/dvd2
mount –o loop /mnt/vmManagement_dvd1.iso /mnt/dvd1
mount –o loop /mnt/vmManagement_dvd2.iso /mnt/dvd2
cat /mnt/dvd1/vmManagement.img.gz0 /mnt/dvd2/vmManagement.img.gz1 > vmManagement.img.gz
gunzip –c /mnt/vmManagement.img.gz > /mnt/virtualmachines/images/vmManagement.img
start the vmManagement : $BICS_HOME/bin/management _cmd start
go to windows and launch the c:/temp/postfactory/postfactory.vbs script (Note : the windows password is
default password Sdfghjk1 see in the installation manual/VMmanagement postinstallation). Caution : you
have to wait that windows stops automatically, the postfactory.vbs could be very long until a hour.
do not forget to replace the nmc.license file in c:\8770\etc\
on the server launch the "management_cmd updatekey" command
TG0064