1.
Slide the captured bearing end of the Take Away Roll shaft into the bearing hole at
the front of the HCF frame (Figure 3).
2.
Reinstall the Bearing into the bearing hole at the rear of the HCF.
3.
Place Gear 22 over the Bearing and hold it there while you reinstall the Take Away
Roll shaft.
4.
Slide the rear of the Take Away Roll shaft through the bearing and Gear 22.
5.
Reposition the shaft so the captured bearing at the front end of the shaft rests in the
bearing hole at the front of the HCF.
6.
Use an E-ring to secure Gear 22 to the Take Away Roll shaft.
7.
Reinstall the Bracket to the HCF frame, and use two screws to secure it frame.
8.
Reconnect J211 and J213 to the Bracket, and route the wire harness through the
harness clips.
9.
Reconnect P/J211 to Tray 3 Feed Clutch.
10.
Reinstall the Inner Chute to the HCF frame, and use two screws to secure it to the
frame.
11.
Reinstall the Spring to the left side of the Inner Chute.
12.
Reinstall the HCF Left Cover.
13.
Reinstall the Rear Cover.
14.
Slide Tray 5 back into the HCF.
4025 Options
4-91