Full Stack Actuator

Removal
1.
2.
3.
4.
Replacement
1.
2.
3.
4.
5.
4-48
Service Manual
Remove the Actuator Cover Assembly.
Turn the Actuator Cover upside down.
Hold the center of Full Stack Actuator 2 between your fingers and bow the Actuator
just enough to free one end of it from the Actuator Cover, and remove the Actuator.
Pull the outside end of Full Stack Actuator 1 free of the Actuator Cover, and remove
the Actuator.
Position Full Stack Actuator 1 as shown.
Reinstall Full Stack Actuator 1 by first sliding the inside end of the Actuator into the
inside slot in the Actuator Cover, and then pressing the outside end of the Actuator
into the slot near the edge of the Cover.
Position Full Stack Actuator 2 as shown.
Reinstall Full Stack Actuator 2 by first sliding the inside end of the Actuator into the
inside slot in the Actuator Cover, and then pressing the outside end of the Actuator
into the slot near the edge of the Cover.
Reinstall the Actuator Cover Assembly.