Table of Contents
Table of Contents
5
Introduction
11
Important Messages
11
System Overview
15
IMX-M General Overview
16
IMX-M Rack and Components
16
IMX-M System Main Parts
17
IMX-M's Unique Features
17
Condition Monitoring Module (CMM) Buffer Storage Capacity
18
Initiating an IMX-M
18
IMX-M Mean Time to Failure (MTTF)
19
Protection
21
Safety Considerations
21
Accuracy
22
Facts to Consider Regarding Accuracy
22
Accuracy Is Relative to API 670 Defined Full Scale
23
Measurement Types
24
Absolute Shaft Vibration
25
Casing Vibration
26
Complementary Differential Expansion
27
Eccentricity
28
Gap
28
Supported Sensor-Types
29
Other
29
Current (4-20 Ma) or Voltage (0-10 V)
29
Measurement with Voltage Output Sensor
29
Precautions / Special Care
29
Configurable Engineering Units
31
Piston Rod Drop
32
Piston Rod Drop Physical Properties
32
Operating Modes
33
Piston Rod Drop Combined Measurement
37
Trigger System and Measuring Angles
37
Trigger Physical Interface
39
Using Digital Input as Measurement Trigger
40
Position
40
Radial Shaft Vibration
41
Speed
41
Temperature
41
Alarms
42
Trip Multiply Factor
42
Alarm Status Propagation
43
Alarm Trigger Filtering
44
Hysteresis
44
Alarm Delayed Trigger and Release
45
First out Indication
46
Relays
47
Relays on Relay Modules
48
Safety Consideration When Configuring Relays
51
Slot Status Relays on Protection Module
52
Behavior of Relay at Channel Startup
54
Protection Part Operation
55
Startup
55
Circuit Faults (Cf)
56
PRM Circuit Faults
57
RLM Circuit Faults
62
CMM Circuit Faults
66
Bit Representation of Combined Conditions
67
Local Display and Local Display Selection Keypad
69
Bargraph Display
70
Start Menu
70
Buffered Outputs Front Menu
72
Channel Values
73
Channel Action
74
Disarm
78
Channel Disarm
78
Rack Disarm
78
Slot Disarm
78
Release of Rack/Slot Disarm after Configuration
80
Protection Configuration Update
80
Protection Firmware Update
81
IMX-M Manager
82
Installation of IMX-M Manager
82
Introduction to IMX-M Manager
82
Project Creation and Configuration Flow
85
Launching the Application
86
Creating a New Project
86
Editing an Existing Project
87
Entering Administration Mode
88
File" Menu Selection
88
Navigating IMX-M Manager Main Menu
88
Serial Communication" Menu Selection
94
Show" Menu Selection
94
Disarming a Slot
101
Sending Protection Configuration to PRM
101
Sending Protection Configuration to Protection Module
101
Validating and Saving Protection Configurations
101
Checking for Circuit Faults
102
Establishing a Connection between Host PC and Protection Module
103
Getting Protection Configuration from Protection Module
103
Export to Excel File
104
Generate Report File
105
Import from Excel File
105
Maintenance View
105
Status
107
Analog
108
Combined Meas
108
Digital
109
Relays
110
Utilities
110
Acceptance Test
111
Protection Module Configuration with IMX-M Manager
115
Adding a Plant Node
115
Building a Configuration Hierarchy
115
Adding an Area Node
116
Adding Rack, Slot and Relay Nodes
116
Setting Slot Properties
118
Assigning Protection Settings (PRM)
119
Configuring Network Settings (CMM)
119
Saving a Network Configuration
124
Configuring a Slot
125
Configuring Analog Channels
125
Updating Network Configuration
125
Initiating an Analog Channel
127
Configuring an Analog Channel
130
Configuring Combined Measurements
139
Identification
140
Sensor
141
Acquisition
142
Alarm Levels
143
Configuring Digital Channels
146
General Settings for Speed Type
148
Alarm Levels for Speed Type
149
Configuring 4-20 Ma Outputs
150
Configuring a Relay Module
151
Available Relay Types
153
General Settings for Relays
154
Channel Setup for Relays
156
Basic Analog and Digital Channel Setup
160
Advanced Analog and Digital Channel Setup
161
Absolute Shaft Vibration
163
Configuration Examples
163
Complementary Differential Expansion
171
Piston Rod Drop (PRD)
180
Gap
191
Other
193
Modbus
200
Exported (Read) Modbus Registers
200
Modbus (L1, L2) for PRM
200
Imported (Write Single) Modbus Registers
215
Modbus (L3) for CMM
216
Condition Monitoring
217
Condition Monitoring Part Operation
217
Condition Monitoring Data Analysis
217
IMX-M Time
217
Automatic Time Synchronization
217
Manual Set Time
218
Hardware
219
Installation
219
Scenario
219
Rack / Cabinet
220
Cooling
221
General Electrical Interface
224
Sensor Cables
224
Supply Cable
224
Signal Grounding
225
Signal Isolation
226
Mains Power
227
Power Supply
229
Inrush Current
230
Power Fuses
230
Sensor Power Output
230
Condition Monitoring Part Electrical Interface
231
Communication Cable
231
Data Communication
231
Ethernet Cable
231
Hardware Configuration
231
General Configuration
232
Analog Inputs
232
Digital Inputs
237
Buffered Outputs
241
Protection Part Configuration
242
RS485 Modbus
242
4-20 Ma Output
243
Protection Module Serial (USB) Interface
244
Condition Monitoring Part Configuration
245
Condition Monitoring Module Serial (USB) Interface
245
LED Indicators
247
Power Supply Unit (PSU)
247
Relay Module (RLM)
248
Condition Monitoring Module (CMM)
249
Protection Module (PRM)
250
Protection Part Diagnostic Commands
254
Condition Monitoring Part Diagnostic Commands
255
Network Related Condition Codes
255
Hardware Maintenance
256
Maintenance of Sensors
256
Ventilation Fan
256
Hot-Swap
256
Changing Modules
260
Changing Module Labels
261
Event Log
263
Troubleshooting Guide Problems and Symptoms
268
Component Check
269
Firmware Recovery
274
Problem
274
Resolution
274
Technical Data
277
Environmental
277
Rack
277
Power Consumption
278
Analog Inputs - Protection & CM
278
Digital Inputs - Protection & CM
278
Outputs - Protection
278
Analog Measurement - Protection
279
Digital Measurement - Protection
279
Relay - Protection
279
Signal Processing - Protection
280
Interface - Protection
280
Analog Measurement - CM
280
Digital Measurement - CM
281
Signal Processing - CM
281
Interface - CM
281
Miscellaneous
281
Quality Control
282
Drawings and Connections
283
IMX-M Rack Drawing with Dimensions
283
Front Panel
284
Rear Panel
285
Power Supply Unit (PSU)
286
Relay Module (RLM)
287
Condition Monitoring Module (CMM)
288
Protection Module (PRM)
289
CMM + PRM Slot Connections
290
Analog Inputs
290
Digital Inputs
291
RS485, Relay Outputs, Rack Disarm
291
Buffered Analog Channel out
292
Buffered Digital Channel out
292
4-20 Ma out
293
Relay Module (RLM) Connections
294
DIP Switches on Protection Module
297
DIP Switch and Jumper on Condition Monitoring Module
298
Part Number Information
299
Main Components
299
Add-On Modules
300
Components
300
Spare Parts & Accessories
301
Wiring Connector Blocks
301
Electrical Waste
303
Glossary
305
Limited Warranty
307
Advertisement
Advertisement
Related Products
SKF MicroDosage System
SKF MDS
SKF Multilog On-line System IMx-T
SKF Multilog On-Line System IM-P Series
SKF Multilube
SKF Multilog WVT
SKF Multilog IMx-S Series
SKF MAX-1-2-24-X-U-V2
SKF Magforce WSP Series
SKF Magforce ASM Series
SKF Categories
Water Pump
Measuring Instruments
Lubrication systems
Tools
Industrial Equipment
More SKF Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL