I2 Inmetro Intrinsic Safety; N2 Inmetro Type N: Non-Sparking - Emerson Rosemount 5408 Reference Manual

Level transmitters non-contacting radar
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Product Certifications
Standards: ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-1:2016, ABNT NBR IEC
Markings:
Specific Conditions of Use (X):
1.
B.12.2

I2 INMETRO Intrinsic Safety

Certificate: UL-BR 17.0344X
Standards: ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-11:2013, ABNT NBR IEC
Markings:
Safety parameter
Voltage U
Current I
Power P
Capacitance C
Inductance L
Specific Conditions of Use (X):
1.
B.12.3

N2 INMETRO Type N: Non-Sparking

Certificate:
Standards:
Markings:
Specific Conditions of Use (X):
1.
210
60079-26:2016, ABNT NBR IEC 60079-31:2014
Ex db IIC T6...T2 Ga/Gb
Ex tb III C T85°C...T250°C Db
Tamb = -60° to +70°C; IP6X
See certificate.
60079-26:2016, ABNT NBR IEC 60079-31:2014
Ex ia IIC T4...T2 Ga
Ex ib IIC T4...T2 Ga/Gb
Ex ia IIIC T85°C...T250°C Da
Tamb = -60° to +70°C
i
i
i
i
i
See certificate.
UL-BR 17.0344X
ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-15:2012
Ex nA IIC T4...T2 Gc
Tamb = -34° to +70°C; IP65
V≤42.4V, I≤23 mA
See certificate.
HART
30 V
133 mA
1.0 W
7.3 nF
0
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis