Spare Parts List - Transmitter Head - Emerson Rosemount 5408 Reference Manual

Level transmitters
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Reference Manual
00809-0100-4408
Parabolic antenna
316/316L SST (EN 1.4404)
PTFE fluoropolymer
FVMQ fluorosilicone (O-ring)
A.4 

Spare parts list - transmitter head

A.4.1 
Required model components
Model
Code
Description
5408
Radar Level Transmitter
Profile
Code
Description
A
Standard monitoring & control applications
F
(1)
Functional safety / SIS applications
(1)
The Rosemount 5408:SIS has two operational modes: Safety (SIS) and Control/Monitoring. Safety (SIS) mode
must be set when used in Safety Instrumented Systems. Control/Monitoring mode is intended for use in a
Basic Process Control System (BPCS).
Measurement type
Code
Description
1
Liquid level measurement
3
Solids level measurement
4
(1)
Liquid & solids level measurement
(1)
Note that for the Rosemount 5408:SIS (profile code F), solids level measurement is only available when
operating in Control/Monitoring mode.
Performance class
Code
Description
A
Ultra accuracy
S
Standard
Signal output
Code
Description
H
4–20 mA with HART
6)
Rosemount 5408 and 5408:SIS Level Transmitters
communication (default output from factory is HART 7, add option code HR6 for HART
®
Specifications and reference data
March 2023
Reference accuracy
±0.04 in. (±1 mm)
±0.08 in. (±2 mm)
 
 
 
163