Transmitter Overview
2.6

System integration

The transmitter is loop-powered, and uses the same two wires for power supply and
output signal. The output is a 4-20 mA analog signal superimposed with a digital HART
signal. The transmitter can be configured for either HART Revision 6 (default) or 7 (option
code HR7). The HART Revision can be switched in field.
By using the optional Rosemount 333 HART Tri-Loop
converted into three additional 4-20 mA analog signals. With the HART protocol,
multidrop configuration is possible. In this case, communication is restricted to digital,
since current is fixed to the 4 mA minimum value.
The transmitter can be combined with the Emerson
wirelessly communicate HART data with IEC 62591 (WirelessHART
addition, the transmitter can be connected to a Rosemount 751 Field Signal Indicator, or it
can be equipped with an LCD display.
The transmitter can easily be configured by using a PC with the Rosemount Radar Master
Plus software (running in the Instrument Inspector
the AMS Device Manager, or any other Device Descriptor (DD) or Field Device Integration
(FDI) compatible host system.
The Rosemount 5408 and 5408:SIS are compliant with NAMUR NE 107 Field Diagnostics
for standardized device diagnostic information.
10
, the digital HART signal can be
Wireless 775 THUM
Adapter to
®
) technology. In
Application), a Field Communicator,
Reference Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents