Incoming air supply specification
Maximum pressure: 190 psi (13 bar)
Recommended pressure: 100 to 115 psi (7 to 8 bar)
Inlet/outlet connection: BSPP (G) ⅜-in.
Air consumption: 252 gal/min at 65 psi (955 l/min at 4.5 bar)
A.3 

Physical specifications

A.3.1 
Material selection
Emerson provides a variety of Rosemount products with various product options and
configurations, including materials of construction that can be expected to perform well
in a wide range of applications. The Rosemount product information presented is intended
as a guide for the purchaser to make an appropriate selection for the application. It is the
purchaser's sole responsibility to make a careful analysis of all process parameters (such
as all chemical components, temperature, pressure, flow rate, abrasives, contaminants,
etc.), when specifying product, materials, options, and components for the particular
application. Emerson is not in a position to evaluate or guarantee the compatibility of
the process fluid or other process parameters with the product, options, configuration, or
materials of construction selected.
A.3.2 
Transmissible Spongiform Encephalopathy (TSE)
declaration
This declaration is applicable to Tri Clamp connections.
Emerson certifies no process wetted components used in this product contain substances
of animal origin. Materials used in the production or processing of wetted components for
this product meet the requirements stated in EMA/410/01 Rev. 3 and ISO 22442-1:2015.
Wetted components in this product are considered free of TSE.
A.3.3 
Engineered solutions
When standard model codes are not sufficient to fulfill requirements, please consult the
factory to explore possible Engineered Solutions. This is typically, but not exclusively,
related to the choice of wetted materials or the design of a process connection. These
Engineered Solutions are part of the expanded offerings and may be subject to additional
delivery lead time. For ordering, factory will supply a special P-labeled numeric option code
that should be added at the end of the standard model string.
A.3.4 
Housing and enclosure
Electrical connections
Two cable/conduit entries (½-14 NPT, M20 x 1.5, or G½)
Optional adapters: M12 4-pin male eurofast connector or A size Mini 4-pin male minifast
connector
Rosemount 5408 and 5408:SIS Level Transmitters
Specifications and reference data
March 2023
161

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents