A.2
Functional specifications
A.2.1
General
Field of application
Continuous level measurements for tank monitoring, process control, and overfill
prevention on a broad range of liquids, slurries, and solids.
Ideal for applications with varying and harsh process conditions, such as heavy turbulence,
foaming, product build-up, condensing vapors, sticky, viscous, corrosive, and crystallizing
products.
Measurement principle
Frequency Modulated Continuous Wave (FMCW)
Frequency range
24.05 to 27.0 (26.5
Maximum output power
-5 dBm (0.32 mW)
Internal power consumption
< 1 W in normal operation
Humidity
0 - 100% relative humidity, non-condensing
Turn-on time
< 40 s
A.2.2
Display and configuration
LCD display (option code M5)
•
•
(5) 26.5 GHz in Australia and New Zealand, and for LPR (Level Probing Radar), option code OA.
(6) Time from when power is applied to the transmitter until performance is within specifications.
Rosemount 5408 and 5408:SIS Level Transmitters
(5)
) GHz
(6)
Toggles between selected output variables
Shows diagnostic information (alerts)
Specifications and Reference Data
151