Table 2-7 Enclosure Status Led Displays - Compaq StorageWorks DS-BA370 Series User Manual

Ultrascsi raid enclosure
Table of Contents

Advertisement

Table 2–7
Enclosure Type
Data
Center
Cabinet
LED is O
N
LED is O
FF
Operating the UltraSCSI Enclosure
Enclosure Status LED Displays
Dept.
Possible Corrective Actions
Server
Cabinet
The enclosure is operating normally. There
are no detected errors.
There are one or more failed components:
1.
Observe the EMU front panel to see if
there is an overtemperature condition,
a blower problem, or a power problem.
Replace the defective blower or power
components.
2.
Observe individual disk drive SBBs for
an error condition.
3.
Check the array controller optional
system maintenance terminal for error
messages.
Either there is no power applied to the
enclosure or the enclosure is in a reset state:
1.
Ensure that ac power is present at the ac
input boxes and that the array controllers
are operational.
2.
Ensure that there are at least four
operational power supplies.
3.
Check the array controller optional
system maintenance terminal for error
messages.
Description and
UltraSCSI RAID Enclosure 2–15

Advertisement

Table of Contents
loading

Table of Contents