Environmental Monitoring Unit
3–30 UltraSCSI RAID Enclosure
Table 3–10 Installing an EMU (Continued)
3.
Pull the EMU extractor latches outward. Push the EMU into the slot
until the extractor latches engage the enclosure, then push the
extractor latches inward to seat and secure the EMU.
4.
If there are no expansion enclosures, go to step 6.
For an expansion configuration, use a BN26M series cable (see Table
3–1) to create the EMU-EMU communications bus connections as
illustrated below.
5.
If there are expansion
enclosures, turn O
N
input boxes for each
expansion enclosure by
pressing I on each ac power
switch (C
1).
ALLOUT
6.
Turn O
all the ac input
N
boxes for the master
enclosure by pressing I on
each ac power switch
(C
1).
ALLOUT
7.
After the array controller is operational, verify that the subsystem is
functioning properly.