Shutting Down The Subsystem; Standby Power Mode; Full Power Shutdown - Compaq StorageWorks DS-BA370 Series User Manual

Ultrascsi raid enclosure
Table of Contents

Advertisement

Operating the UltraSCSI Enclosure

Shutting Down the Subsystem

2–8 UltraSCSI RAID Enclosure
Shutting down the subsystem involves:
Clearing the cache module
Shutting down the controller
Either turning O
the dc power for the subsystem (entering the
FF
standby power mode) or going one step further and turning O
the ac input boxes (full power shutdown)
Failure to clear the cache module and shut down the array
controller before removing power will disrupt data
transfers. Therefore, always shut down the array controller
as described in the array controller documentation.
Some array controllers bypass the standby power mode
functionality from the PVA standby power switch. Refer to
the array controller documentation for availability of this
feature.

Standby Power Mode

Placing the subsystem in the standby power mode disconnects the dc
power from the backplane. However, ac input power is still applied to
the shelf power supplies. In this mode, the EMU alarm control switch
now functions as the standby power switch. To restore the dc power to
the backplane, press the alarm control switch on each enclosure
EMU.

Full Power Shutdown

Powering down an enclosure always involves shutting down the array
controller and then pressing the PVA standby power switch on each
expansion enclosure. If there are no expansion enclosures, shut down
the array controller and then press the PVA standby power switch on
the master enclosure.
Turning the subsystem off involves shutting down the array controller,
turning O
the dc power, and then turning O
FF
each enclosure.
Caution
the ac input boxes in
FF
FF

Advertisement