Single-Ended I/O Module
5–6 UltraSCSI RAID Enclosure
Only when all I/O modules are the same type can an UltraSCSI RAID
subsystem function properly. The Compaq UltraSCSI controller only
supports single-ended buses. Therefore, use only single-ended I/O
modules (DS–BA35X–MN). The enclosure does not support the
following conditions:
Improperly installing a single-ended I/O module
Installing fewer than six single-ended I/O modules
Installing a termination I/O module
Installing a differential I/O module

TERMPOWER Errors

The I/O module displays a TERMPOWER status indication for both
the internal and external bus as shown in Figure 5–4.
Figure 5–4 I/O Module TERMPOWER LEDs
1
The nominal TERMPOWER for both buses is +5 V dc.
The green internal (C
ALLOUT
TERMPOWER LEDs are O
If a TERMPOWER overcurrent condition exists or there is no