Product Description; Figure 3-2 Emu Location - Compaq StorageWorks DS-BA370 Series User Manual

Ultrascsi raid enclosure
Table of Contents

Advertisement

Environmental Monitoring Unit

Product Description

3–2 UltraSCSI RAID Enclosure
The EMU detects enclosure error conditions and configuration faults,
and then notifies the user of existing or impending failures, using one
or more of the following error reporting systems:
EMU LEDs
EMU audible alarm
Error messages on the host interface
Enclosure LEDs
The EMU (C
1) mounts directly above array controller "A"
ALLOUT
(upper bus controller) as shown in Figure 3–2.
Figure 3–2 EMU Location
1
2
In some instances [such as a blower failure, a high intake air
temperature, or a high internal enclosure (exhaust) temperature], the
EMU automatically initiates corrective action. For example, the EMU
will command the blowers to operate at high-speed to prevent
component damage due to an overtemperature condition. In a severe
case, the EMU might even turn O
Figure C
1.
EMU
2.
PVA
CXO5754B
the enclosure power.
FF
ALLOUTS

Advertisement