Installing EMU Microcode

Preparing the EMU

Loading the Microcode
C–4 UltraSCSI RAID Enclosure
Complete the procedure in Table C–2 to prepare the EMU for loading
the microcode.
Table C–2 Preparing the EMU
1.
On the master enclosure, press and hold-in the alarm control switch
while removing the EMU from the enclosure.
The PVA audible alarm sounds, indicating that there is no EMU in
the enclosure, and continues to sound until the EMU is reinserted.
2.
While still holding-in alarm control switch, insert the EMU into the
enclosure and firmly seat it.
The PVA audible alarm turns O
(green), and eight blower (amber) LEDs will be O
3.
Continue holding in the alarm control switch until:
The blower LEDs are O
The PC monitor displays the following message:
Waiting for receiver ready
4.
Release the alarm control switch.
From the PC, initiate the upload function by completing the
procedure in Table C–3.
Table C–3 Loading the Microcode
1.
When using PROCOMM PLUS, press the Send File Key.
2.
Select Raw ASCII from the protocol list.
3.
Enter the microcode path and filename (for example,
C:\FLSH_011.HEX).
4.
When the EMU microcode download starts, all blower LEDs are O
and the PC displays a series of messages similar to those shown in
Table C–4.
. The temperature (amber), power
FF
.