Procedures For Replacing A Disk Drive Sbb; Table 7-3 Removing A Disk Drive Sbb - Compaq StorageWorks DS-BA370 Series User Manual

Ultrascsi raid enclosure
Table of Contents

Advertisement

Storage Devices
7–10 UltraSCSI RAID Enclosure

Procedures for Replacing a Disk Drive SBB

Complete the procedure in Table 7–3 to remove a disk drive SBB.
When initially installing disk drive SBBs in an enclosure or installing
a single disk drive SBB, complete the procedure in Table 7–4.
Table 7–3
Removing a Disk Drive SBB
1.
To perform a hot swap, go to step 8.
2.
To perform a warm swap, quiesce the SCSI bus using array controller
documentation, then go to step 8.
3.
To perform a cold swap, shut down the subsystem using array
controller documentation.
4.
If there are no expansion enclosures, go to step 5.
If there are expansion enclosures, press and hold the PVA standby
power switch (C
ALLOUT
master EMU initiates a power shut down on all enclosures.
5.
Press and hold the PVA standby power switch (C
master enclosure until the master EMU initiates a power shut down
on the master enclosure.
1) on an expansion enclosure until the
1
CXO6303A
ALLOUT
1) on the

Advertisement